Qualcomm's QPNP PMIC Voltage ADC Arbiter

QPNP PMIC Voltage ADC (VADC) provides interface to clients to read
Voltage. A 15 bit ADC is used for Voltage measurements. There are multiple
peripherals to the VADC and the scope of the driver is to provide interface
for the USR peripheral of the VADC.

VADC node

Required properties:
- compatible : should be "qcom,qpnp-vadc" for Voltage ADC driver.
- reg : offset and length of the PMIC Aribter register map.
- interrupts : The USR bank peripheral VADC interrupt.
- qcom,adc-bit-resolution : Bit resolution of the ADC.
- qcom,adc-vdd-reference : Voltage reference used by the ADC.

Channel nodes
NOTE: Atleast one Channel node is required.

Required properties:
- label : Channel name used for sysfs entry.
- qcom,channel-num : Channel number associated to the AMUX input.
- qcom,decimation : Sampling rate to use for the individual channel measurement.
		    Select from following unsigned int.
		    0 : 512
		    1 : 1K
		    2 : 2K
		    3 : 4K
- qcom,pre-div-channel-scaling : Pre-div used for the channel before the signal
				 is being measured.
- qcom,calibration-type : Reference voltage to use for channel calibration.
			  Channel calibration is dependendent on the channel.
			  Certain channels like XO_THERM, BATT_THERM use ratiometric
			  calibration. Most other channels fall under absolute calibration.
			  Select from the following strings.
			  "absolute" : Uses the 625mv and 1.25V reference channels.
			  "ratiometric" : Uses the reference Voltage/GND for calibration.
- qcom,scale-function : Scaling function used to convert raw ADC code to units specific to
			a given channel.
			Select from the following unsigned int.
			0 : Default scaling to convert raw adc code to voltage.
			1 : Conversion to temperature based on btm parameters.
			2 : Returns result in milli degree's Centigrade.
			3 : Returns current across 0.1 ohm resistor.
			4 : Returns XO thermistor voltage in degree's Centigrade.
- qcom,hw-settle-time : Settling period for the channel before ADC read.
			Select from the following unsigned int.
			0 : 0us
			1 : 100us
			2 : 200us
			3 : 300us
			4 : 400us
			5 : 500us
			6 : 600us
			7 : 700us
			8 : 800us
			9 : 900us
			0xa : 1ms
			0xb : 2ms
			0xc : 4ms
			0xd : 6ms
			0xe : 8ms
			0xf : 10ms
- qcom,fast-avg-setup : Average number of samples to be used for measurement. Fast averaging
			provides the option to obtain a single measurement from the ADC that
			is an average of multiple samples. The value selected is 2^(value)
			Select from the following unsigned int.
			0 : 1
			1 : 2
			2 : 4
			3 : 8
			4 : 16
			5 : 32
			6 : 64
			7 : 128
			8 : 256

Example:
	/* Main Node */
	qcom,vadc@3100 {
                        compatible = "qcom,qpnp-vadc";
                        reg = <0x3100 0x100>;
                        interrupts = <0x0 0x31 0x0>;
                        qcom,adc-bit-resolution = <15>;
                        qcom,adc-vdd-reference = <1800>;

			/* Channel Node */
                        chan@0 {
                                label = "usb_in";
                                qcom,channel-num = <0>;
                                qcom,decimation = <0>;
                                qcom,pre-div-channel-scaling = <20>;
                                qcom,calibration-type = "absolute";
                                qcom,scale-function = <0>;
                                qcom,hw-settle-time = <0>;
                                qcom,fast-avg-setup = <0>;
                        };
	};